|  Execution standard:  GB/T 7551-2008 Certificate (eqv OIML R60) Combined error : 0.027% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.  | 
     
      
  | 
 
Dimensions : (In mm.  1mm = 0.03937 inches) 
 ![]()  | 
     ![]()  | 
 
| 
      CAP./SIZE  | 
     
      A  | 
     
      B  | 
     
      C  | 
     
      D  | 
     
      E  | 
     
      F  | 
     
      H  | 
     
      K  | 
     
      L  | 
 
| 
      20~50 klbs  | 
     
      190.5  | 
     
      114.3  | 
     
      57.1  | 
     
      31.8  | 
     
      12.7  | 
     
      19.1  | 
     
      63.5  | 
     
      60.3  | 
     
      3/8-24  | 
 
| 
      100klbs  | 
     
      231.8  | 
     
      152.4  | 
     
      79.4  | 
     
      44.5  | 
     
      15.9  | 
     
      27.0  | 
     
      64.3  | 
     
      101.6  | 
     
      1/2-20  | 
 
| 
      200klbs  | 
     
      295.3  | 
     
      203.2  | 
     
      114.3  | 
     
      63.5  | 
     
      15.9  | 
     
      27.0  | 
     
      89.7  | 
     
      139.7  | 
     
      5/8-18  | 
 
| 
      300klbs  | 
     
      355.8  | 
     
      252  | 
     
      127  | 
     
      76.2  | 
     
      19.1  | 
     
      33.3  | 
     
      109.5  | 
     
      139.7  | 
     
      3/4-16  | 
 
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
<=50klbs: 3.0 m, >=100klbs: 10m.
Diameter:Φ6
Connection:
Refer to the following drawing:
 
Notice:Do not change the length of cable, or lese, it will effect the sensitivity of load cell.
Specification
| 
      Item Parameter  | 
     
      C3  | 
     
      Unit  | 
 
| 
      Rated load (Emax):  | 
     
      20,30,50,100,200,300  | 
     
      klbs  | 
 
| 
       Maximal numbers of load cell verification  | 
     
      3000  | 
     
      d  | 
 
| 
      Minimum load cell verification intervals Intervals ( Vmin):  | 
     
      0.01  | 
     
      % of rated load  | 
 
| 
      Rated output (Cn):  | 
     
      2.0±0.1%  | 
     
      mV/V  | 
 
| 
      Combined error:  | 
     
      0.015  | 
     
      -% of rated output  | 
 
| 
      Temperature effect on sensitivity(Tkc):  | 
     
      0.0012  | 
     
      =% of rated output/  | 
 
| 
      Temperature effect on zero balance(Tk0):  | 
     
      0.0008  | 
     
      -% of rated output  | 
 
| 
      Zero balance:  | 
     
      1.0  | 
     
      -% of rated output  | 
 
| 
      Input resistance(Rlc):  | 
     
      775±5  | 
     
      Ω(Ohms)  | 
 
| 
      Output resistance(Ro):  | 
     
      702±2  | 
     
      Ω(Ohms)  | 
 
| 
      Insulation resistance:  | 
     
      ≥5000  | 
     
      MΩ (Mega-Ohms)  | 
 
| 
      Safe overload:  | 
     
      150  | 
     
      % of rated capability  | 
 
| 
      Ultimate overload:  | 
     
      300  | 
     
      % of rated capability  | 
 
| 
      Operating temperature range:  | 
     
      -20~+70/-20~+160  | 
     
      ℃/ °F  | 
 
| 
      Recommend excitation:  | 
     
      8~15  | 
     
      V( DC or AC)  | 
 
| 
      Maximum excitation:  | 
     
      24  | 
     
      V( DC or AC)  | 
 
| 
      Material of elastomer:  | 
     
      Alloy steel / Stainless steel  | 
 |
| 
      Protection class:  | 
     
      IP67/IP68  | 
 |
Hotline.
Ms. Vân Anh - 0904883101