|  Execution standard:  GB/T 7551-1997 Certificate (eqv OIML R60) Combined error: 0.015% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.  | 
     
      
  | 
 
Dimensions
(In mm. 1mm = 0.03937 inches)

| 
      CAP./SIZE  | 
     
      L  | 
     
      L1  | 
     
      L2  | 
     
      L3  | 
     
      L4  | 
     
      H  | 
     
      H1  | 
     
      H2  | 
     
      W  | 
     
      W1  | 
     
      M  | 
     
      N-D  | 
     
      R  | 
 
| 
      1,2,3t  | 
     
      320  | 
     
      230  | 
     
      145  | 
     
      120  | 
     
      275  | 
     
      85  | 
     
      18  | 
     
      25  | 
     
      40  | 
     
      -  | 
     
      M12  | 
     
      2- Φ18  | 
     
      60  | 
 
| 
      5,7,10t  | 
     
      310  | 
     
      240  | 
     
      145  | 
     
      120  | 
     
      275  | 
     
      100  | 
     
      18  | 
     
      30  | 
     
      50  | 
     
      25  | 
     
      M12  | 
     
      4- Φ13  | 
     
      60  | 
 
| 
      15,20,30t  | 
     
      390  | 
     
      300  | 
     
      210  | 
     
      180  | 
     
      345  | 
     
      127  | 
     
      20  | 
     
      45  | 
     
      56  | 
     
      29  | 
     
      M16  | 
     
      4- Φ18  | 
     
      80  | 
 
| 
      40,50,60t  | 
     
      500  | 
     
      395  | 
     
      235  | 
     
      200  | 
     
      445  | 
     
      173  | 
     
      21  | 
     
      67  | 
     
      86  | 
     
      45  | 
     
      M20  | 
     
      4- Φ22  | 
     
      90  | 
 
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
1~3t: 3m, 5~10t: 6m, >=20t:10m
Diameter: Φ6
Connection:
Refer to the following drawing:

Notice: Do not change the length of cable, or lese, it will effect the sensitivity of loadcell.
Specification
| 
      Item Parameter  | 
     
      C3  | 
     
      Unit  | 
 
| 
      Rated load (Emax):  | 
     
      1~60  | 
     
      t  | 
 
| 
      Maximal numbers of load cell verification Intervals (Nlc):  | 
     
      3000  | 
     
      d  | 
 
| 
      Minimum load cell verification intervals Intervals ( Vmin):  | 
     
      0.01  | 
     
      % of rated load  | 
 
| 
      Rated output (Cn):  | 
     
      2.0±0.1%  | 
     
      mV/V  | 
 
| 
      Combined error:  | 
     
      0.015  | 
     
      -% of rated output  | 
 
| 
      Temperature effect on sensitivity(Tkc):  | 
     
      0.0012  | 
     
      =% of rated output/  | 
 
| 
      Temperature effect on zero balance(Tk0):  | 
     
      0.0008  | 
     
      -% of rated output  | 
 
| 
      Zero balance:  | 
     
      1.0  | 
     
      -% of rated output  | 
 
| 
      Input resistance(Rlc):  | 
     
      775±5  | 
     
      Ω(Ohms)  | 
 
| 
      Output resistance(Ro):  | 
     
      702±2  | 
     
      Ω(Ohms)  | 
 
| 
      Insulation resistance:  | 
     
      ≥5000  | 
     
      MΩ (Mega-Ohms)  | 
 
| 
      Safe overload:  | 
     
      150  | 
     
      % of rated capability  | 
 
| 
      Ultimate overload:  | 
     
      300  | 
     
      % of rated capability  | 
 
| 
      Operating temperature range:  | 
     
      -20~+70/-20~+160  | 
     
      ℃/ °F  | 
 
| 
      Recommend excitation:  | 
     
      8~15  | 
     
      V( DC or AC)  | 
 
| 
      Maximum excitation:  | 
     
      24  | 
     
      V( DC or AC)  | 
 
| 
      Material of elastomer:  | 
     
      Alloy steel / Stainless steel  | 
 |
| 
      Protection class:  | 
     
      IP67/IP68  | 
 |
Hotline.