|  Execution standard:  GB/T 7551-1997 Certificate (eqv OIML R60) Combined error: 0.015% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.  | 
     
      
  | 
 
Dimensions
(In mm. 1mm = 0.03937 inches)
 ![]()  | 
     
      
  | 
 
| 
      CAP./SIZE(kg)  | 
     
      H  | 
     
      B  | 
     
      W  | 
     
      M  | 
 
| 
      0.5,1t  | 
     
      80  | 
     
      70  | 
     
      26  | 
     
      M12  | 
 
| 
      2,3,5t  | 
     
      108  | 
     
      96  | 
     
      26  | 
     
      M18*1.5  | 
 
| 
      7.5t  | 
     
      140  | 
     
      110  | 
     
      32  | 
     
      M24*2  | 
 
| 
      10t  | 
     
      178  | 
     
      130  | 
     
      51  | 
     
      M30*2  | 
 
| 
      15,20t  | 
     
      190  | 
     
      160  | 
     
      60  | 
     
      M39*2  | 
 
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
0.5~20t: 3m
Diameter: Φ6
Connection:
Refer to the following drawing:

Notice: Do not change the length of cable, or lese, it will effect the sensitivity of loadcell.
Specification
| 
      Item Parameter  | 
     
      C3  | 
     
      Unit  | 
 
| 
      Rated load (Emax):  | 
     
      0.5,1,2,3,5,7.5,10,20  | 
     
      t  | 
 
| 
      Maximal numbers of load cell verification Intervals (Nlc):  | 
     
      3000  | 
     
      d  | 
 
| 
      Minimum load cell verification intervals Intervals ( Vmin):  | 
     
      0.01  | 
     
      % of rated load  | 
 
| 
      Rated output (Cn):  | 
     
      2.0±0.1%  | 
     
      mV/V  | 
 
| 
      Combined error:  | 
     
      0.015  | 
     
      -% of rated output  | 
 
| 
      Temperature effect on sensitivity(Tkc):  | 
     
      0.0012  | 
     
      =% of rated output/  | 
 
| 
      Temperature effect on zero balance(Tk0):  | 
     
      0.0008  | 
     
      -% of rated output  | 
 
| 
      Zero balance:  | 
     
      1.0  | 
     
      -% of rated output  | 
 
| 
      Input resistance(Rlc):  | 
     
      385±5  | 
     
      Ω(Ohms)  | 
 
| 
      Output resistance(Ro):  | 
     
      351±2  | 
     
      Ω(Ohms)  | 
 
| 
      Insulation resistance:  | 
     
      ≥5000  | 
     
      MΩ (Mega-Ohms)  | 
 
| 
      Safe overload:  | 
     
      150  | 
     
      % of rated capability  | 
 
| 
      Ultimate overload:  | 
     
      300  | 
     
      % of rated capability  | 
 
| 
      Operating temperature range:  | 
     
      -20~+70/-20~+160  | 
     
      ℃/ °F  | 
 
| 
      Recommend excitation:  | 
     
      8~15  | 
     
      V( DC or AC)  | 
 
| 
      Maximum excitation:  | 
     
      18  | 
     
      V( DC or AC)  | 
 
| 
      Material of elastomer:  | 
     
      Alloy steel / Stainless steel  | 
 |
| 
      Protection class:  | 
     
      IP67/IP68  | 
 |
Hotline.
Ms. Vân Anh - 0904883101