|  Execution standard:  GB/T 7551-1997 Certificate (eqv OIML R60) Combined error: 0.027% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.  | 
     
         | 
 
Dimensions
(In mm. 1mm = 0.03937 inches)
| 
         | 
     
      
  | 
 
| 
      CAP./SIZE  | 
     
      A  | 
     
      B  | 
     
      C  | 
     
      D  | 
     
      E  | 
     
      F  | 
     
      H  | 
     
      K  | 
     
      SR  | 
 
| 
      10~30t  | 
     
      150  | 
     
      82  | 
     
      40  | 
     
      38  | 
     
      82  | 
     
      34.7  | 
     
      41.7  | 
     
      8  | 
     
      150  | 
 
| 
      40~60t  | 
     
      170  | 
     
      88  | 
     
      53  | 
     
      47  | 
     
      95  | 
     
      43  | 
     
      53  | 
     
      10  | 
     
      200  | 
 
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
<=30t: 12.0 m, >=40t: 18m
Diameter:Φ6
Connection:
Refer to the following drawing:

Notice:
Do not change the length of cable, or lese, it will effect the sensitivity of  loadcell. 
Specification
| 
      Item Parameter  | 
     
      C3  | 
     
      Unit  | 
 
| 
      Rated load (Emax):  | 
     
      10,20,30,40,50,60  | 
     
      t  | 
 
| 
      Maximal numbers of load cell verification Intervals (Nlc):  | 
     
      2000  | 
     
      d  | 
 
| 
      Minimum load cell verification intervals Intervals ( Vmin):  | 
     
      0.02  | 
     
      % of rated load  | 
 
| 
      Rated output (Cn):  | 
     
      2.0±0.1%  | 
     
      mV/V  | 
 
| 
      Combined error:  | 
     
      0.027  | 
     
      -% of rated output  | 
 
| 
      Temperature effect on sensitivity(Tkc):  | 
     
      0.0024  | 
     
      =% of rated output/  | 
 
| 
      Temperature effect on zero balance(Tk0):  | 
     
      0.002  | 
     
      -% of rated output  | 
 
| 
      Zero balance:  | 
     
      1.0  | 
     
      -% of rated output  | 
 
| 
      Input resistance(Rlc):  | 
     
      775±5  | 
     
      Ω(Ohms)  | 
 
| 
      Output resistance(Ro):  | 
     
      702±2  | 
     
      Ω(Ohms)  | 
 
| 
      Insulation resistance:  | 
     
      ≥5000  | 
     
      MΩ (Mega-Ohms)  | 
 
| 
      Safe overload:  | 
     
      150  | 
     
      % of rated capability  | 
 
| 
      Ultimate overload:  | 
     
      300  | 
     
      % of rated capability  | 
 
| 
      Operating temperature range:  | 
     
      -20~+160/-5~+320  | 
     
      ℃/ °F  | 
 
| 
      Recommend excitation:  | 
     
      8~15  | 
     
      V( DC or AC)  | 
 
| 
      Maximum excitation:  | 
     
      24  | 
     
      V( DC or AC)  | 
 
| 
      Material of elastomer:  | 
     
      Alloy steel / Stainless steel  | 
 |
| 
      Protection class:  | 
     
      IP67/IP68  | 
 |