              		 		Parameter of vortex flow meter 
             | 
        
        
            | 
             Measured  
            Mediums 
             | 
            
              		liquids, gases and steams  
            (NOTE: the mediums should be unidirectional  
            or can e seen as unidirectional.) 
             | 
        
        
            | 
              		When the dryness of saturated steams ≥85% 
            , they can be seen as unidirectional. 
             | 
        
        
            | 
              		Temperature  
            of Mediums 
             | 
            
              		- 40°C ~ + 350°C 
             | 
        
        
            | 
              		Pressure of Mediums 
             | 
            
              		1.6MPa, 2.5MPa, 4.0 MPa 
             | 
        
        
            | 
             Accuracy 
             | 
            
             1.0; 1.5 
             | 
        
        
            | 
             Span Rate 
             | 
            
              		1:8 ~ 1:30 (compared with the standard atmospheric pressure) 
             | 
        
        
            | 
              		1:8 ~ 1:40 ( compared with the nominal temperature water) 
             | 
        
        
            | 
              		Flow Range 
             | 
            
              		Liquids: 0.4 ~ 7.0 m/s 
             | 
        
        
            | 
              		Gases: 4.0 ~ 60.0 m/s 
             | 
        
        
            | 
              		Steams: 5.0 ~ 70.0 m/s 
             | 
        
        
            | 
              		Nominal Diameter 
             | 
            
             DN 25, 40, 50, 65, 80, 100, 125, 150, 200, 250,300 mm 
             | 
        
        
            | 
             Materials 
             | 
            
              		1Cr18Ni9Ti 
             | 
        
        
            | 
              		Reynolds No. 
             | 
            
              		Normally, 2*104 ~ 7*106 
             | 
        
        
            | 
              		Resistance  
            Coefficient 
             | 
            
             Cd ≤ 2.6 
             | 
        
        
            | 
             Licensed  
            Vibration Acceleration 
             | 
            
             LUGB type ≤ 0.2g 
             | 
        
        
            | 
              		Class of Protection 
             | 
            
             IP65 
             | 
        
        
            | 
             Class of  
            Explosion-Proof 
             | 
            
              		Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6 
             | 
        
        
            | 
              		Explosion Suppression: Exid II CT4 
             | 
        
        
            | 
              		Conditions of  
            Surroundings 
             | 
            
              		Temperature of 
             Surroundings: 
             | 
            
              		Non-Explosion Proof Surroundings: 
            - 40°C~ +55°C 
             | 
        
        
            | 
              		Explosion-Proof Surroundings: 
            -20°C~ +55°C 
             | 
        
        
            | 
              		Relative Humidity: 
             | 
            
             ≤ 85% 
             | 
        
        
            | 
              		Atmospheric Pressure: 
             | 
            
             86 ~ 106 kPa 
             | 
        
        
            | 
              		Power Supply 
             | 
            
              		Non-Explosion 
            Proof Type 
             | 
            
             Pulse  
            type: 
             | 
            
             +12 VDC  
            ( the output current is 4 ~ 20mA) 
             | 
        
        
            | 
             Current  
            type: 
             | 
            
             +24 VDC  
            ( the output current is 4~ 20mA) 
             | 
        
        
            | 
              		Explosion-Proof Type 
             | 
            
             Current  
            type: 
             | 
            
             +24 VDC  
            ( the output current is 4~20mA) 
             | 
        
        
            | 
              		Output Signal 
             | 
            
              		Frequency pulse signal 2~3000Hz,  
            low level voltage ≤1V, high level voltage ≥ 6V 
             | 
        
        
            | 
              		Two-wire system 4 ~ 20mA signal (isolation output, load ≤ 500Ω. 
             |